Irradiation chamber with 400W or 1000W emitters.

The internal base plate can be inserted into the lateral guides at different heights.

The drawer base is loaded with the products to be irradiated and the door is closed and locked and the irradiation started.

The integral UV emitter is fitted with a shutter. Only after the door is closed and locked can radiation be emitted following the automatic opening of the shutter system.

Should the door be forcibly opened during irradiation, the UV emitter is automatically switched off.

There is an integral power-monitoring UV sensor and if the measured UV output falls below a set value, an alarm is generated.

The system has a small SPS with a display. The required irradiation time can be set and the time already expired is displayed.

There is also a permanently running operating hours clock and an operating hours clock which can be reset.

The irradiation procedure can be stopped if necessary by means of a push button.

UV-Systems - UV-E 400B (with UV Chamber2)
Product Images
  • UV-E 400B (with UV Chamber2)UV-E 400B (with UV Chamber2)
  • UV-E 400B (with UV Chamber2)UV-E 400B (with UV Chamber2)
  • UV-E 400B (with UV Chamber2)UV-E 400B (with UV Chamber2)

UV-E 450B

Drawer/Irradiation chamber with 450W emitters.

The drawer is loaded with the products to be irradiated and pushed into the system, where it is automatically locked and the irradiation commenced.

The integral UV lamp is fitted with a shutter and only after the drawer is locked in position can radiation be emitted following the automatic opening of the shutter system.

Should the door be forcibly opened during irradiation, the UV emitter is automatically switched off.

There is an integral power-monitoring UV sensor and if the measured UV output falls below a set value, an alarm is generated.

The system has a small SPS with a display. The required irradiation time can be set and the time already expired is displayed.

There is also a permanently running operating hours clock and an operating hours clock which can be reset.

The irradiation procedure can be stopped if necessary by means of a push button.

UV-Systems - UV-E 450B
Product Images
  • UV-E 450BUV-E 450B
  • UV-E 450BUV-E 450B
  • UV-E 450BUV-E 450B

UV-E 900B

Irradiation chamber with 900W emitter.

The drawer is loaded with the products to be irradiated and pushed into the system, where it is automatically locked and the irradiation commenced.

The integral UV lamp is fitted with a shutter and only after the drawer is locked in position can radiation be emitted following the automatic opening of the shutter system.

Should the door be forcibly opened during irradiation, the UV emitter is automatically switched off.

There is an integral power-monitoring UV sensor and if the measured UV output falls below a set value, an alarm is generated.

The system has a small SPS with a display. The required irradiation time can be set and the time already expired is displayed.

There is also a permanently running operating hours clock and an operating hours clock which can be reset.

The irradiation procedure can be stopped if necessary by means of a push button.

UV-Systems - UV-E 900B
Product Images
  • UV-E 900BUV-E 900B
  • UV-E 900BUV-E 900B
  • UV-E 900BUV-E 900B

UV-Lightbox

Small lightbox with a manually operated shutter.

The door of the box can be opened only when the shutter is closed preventing radiation from entering the chamber.

When the shutter is open, the door is locked.

No mains voltage supply is necessary for the lightbox.

Adaptor plates are available to fix different UV emitters, such as hand lamps or specific customer instruments.

UV-Systems - UV-Lightbox
Product Images
  • UV-LightboxUV-Lightbox
  • UV-LightboxUV-Lightbox
  • UV-LightboxUV-Lightbox

UV-Lightbox 400

A UV-F 400, 450W large surface emitter in a large lightbox with a manually operated shutter.

The door of the box can be opened only when the shutter is closed preventing radiation from entering the chamber.

When the shutter is open, the door is locked.

No mains supply voltage is necessary for the lightbox and the UV emitter has a separate power supply.

Adaptor plates are available to fix different UV emitters, such as hand lamps, UV-F 400 or specific customer instruments.

UV-Systems - UV-Lightbox 400
Product Images
  • UV-Lightbox 400UV-Lightbox 400
  • UV-Lightbox 400UV-Lightbox 400
  • UV-Lightbox 400UV-Lightbox 400

UV-Lightbox 450

A UV-F 450, 450W large surface emitter in a large lightbox with a manually operated shutter.

The door of the box can be opened only when the shutter is closed preventing radiation from entering the chamber. When the shutter is open, the door is locked.

No mains supply voltage is necessary for the lightbox and the UV emitter has a separate power supply.

Adaptor plates are available to fix different UV emitters, such as hand lamps, UV-F 450 or specific customer instruments.

UV-Systems - UV-Lightbox 450
Product Images
  • UV-Lightbox 450UV-Lightbox 450
  • UV-Lightbox 450UV-Lightbox 450
  • UV-Lightbox 450UV-Lightbox 450
Beispiel
UV-E 400B
UV-E 450B
UV-E 900B
UV-Lightbox
UV-Lightbox 400
Beispiel

10 / 11

Irradiation Chambers Overview