UV-P 250C (without timer)

250W point emitter system with focused optics.

UV-P 250C is a point emitter, which functions without the need of an optic cable.

The UV radiation generated in the device is reflected by a concave mirror and focused by a lens system and projected onto the surface to be irradiated.

This system generates a high intensity UV output.

It is best suited for applications with irradiation surfaces up to 30mm.

The radiation outlet can, optionally, be fitted with a pneumatic shutter/aperture and the shutter is released by a controller provided by the customer.

The housing can be flexibly retrofitted into existing plant or can be fixed to an optional tripod.

The integral lens system is designed for all UV wavelengths and, optionally, an additional filter (eg for black light) can be fitted in the optics.

UV-Systems - UV-P 250C (without timer)
Product Images
  • UV-P 250C (without timer)UV-P 250C (without timer)
  • UV-P 250C (without timer)UV-P 250C (without timer)
  • UV-P 250C (without timer)UV-P 250C (without timer)

UV-P 280-4

UV point emitter system which can be connected to up to 4 optic cables, each of 5m diameter (active core diameter).

Connection to multiple fibre cables is also possible.

The UV radiation produced by the point emitter is coupled into two optic cables (one at the front and one at the back of the instrument) Both cables can be controlled separately.

Irradiation is started by means of a foot switch and irradiation times can be programmed at each cable connection.

Optionally, sensors can be incorporated to monitor the aperture opening.

UV-A filter caps are also optionally available.

UV-Systems - UV-P 280-4
Product Images
  • UV-P 280-4UV-P 280-4
  • UV-P 280-4UV-P 280-4
  • UV-P 280-4UV-P 280-4

UV-P 280-2

UV point emitter system for connection to two optical cables each of 8mm diameter (active core diameter)
The connection of multi-fibre fibre optic cables is also possible.

The UV radiation produced by the point emitter is coupled into two optic cables (one at the front and one at the back of the instrument) Both cables can be controlled separately.

At a workplace where two point light instruments are needed, two tasks can be carried out independently of each other with one device by using a UV-P 280-2.

Radiation is initiated by a foot switch and irradiation times can be programmed at each cable connection.

Optionally, sensors can be incorporated to monitor the aperture opening. UV-A filter caps are also optionally available.

UV-Systems - UV-P 280-2
Product Images
  • UV-P 280-2UV-P 280-2
  • UV-P 280-2UV-P 280-2
  • UV-P 280-2UV-P 280-2

UV-P 280-8

UV point emitter system which can be connected to up to 8 optic cables, each of 5m diameter (active core diameter).

Connection to multiple fibre cables is also possible.

The UV radiation produced by the point emitter is coupled into two optic cables (one at the front and one at the back of the instrument) Both cables can be controlled separately.

Irradiation is started by means of a foot switch and irradiation times can be programmed at each cable connection.

Optionally, sensors can be incorporated to monitor the aperture opening.

UV-A filter caps are also optionally available.

UV-Systems - UV-P 280-8
Product Images
  • UV-P 280-8UV-P 280-8
  • UV-P 280-8UV-P 280-8
  • UV-P 280-8UV-P 280-8

UV-P 280-6

UV point emitter system which can be connected to up to 6 optic cables, each of 5m diameter (active core diameter).

Connection to multiple fibre cables is also possible.

The UV radiation produced by the point emitter is coupled into two optic cables (one at the front and one at the back of the instrument) Both cables can be controlled separately.

Irradiation is started by means of a foot switch and irradiation times can be programmed at each cable connection.

Optionally, sensors can be incorporated to monitor the aperture opening. UV-A filter caps are also optionally available.

UV-Systems - UV-P 280-6
Product Images
  • UV-P 280-6UV-P 280-6
  • UV-P 280-6UV-P 280-6
  • UV-P 280-6UV-P 280-6

UV-P HighEnergy

High intensity UV point emitter system for connecting to an optic cable of maximum 8mm diameter (active core diameter).

Connection to multiple fibre cables is also possible.

Cost-effective high power device (up to 20W/cm²) for universal application.

Simple time control or connection to SPS.

UV-Systems - UV-P HighEnergy
Product Images
  • UV-P HighEnergyUV-P HighEnergy
  • UV-P HighEnergyUV-P HighEnergy
  • UV-P HighEnergyUV-P HighEnergy
Beispiel
UV-P 280-6 (with chamber)
UV-P 280-4
UV-P 280-2
UV-P 280-8
UV-P 280-6
Beispiel

10 / 12

Point Emitters Overview